T6060

DIFFERENTIAL ENTRY-LEVEL LEAK TESTER

Applications:
 
  Aerospace   Mechanical
  Automotive   Medical
  Household Appliances   Oleodynamic
  Electronics   Packaging
  Foundry   Gas
  Pneumatics   Heating
  Valves   Hydraulics
  Brakes   Alternative Energy
  Refrigeration   Cylinders

Model 0-0,2 bar 0-0,5 bar 0-1 bar 0-2 bar 0-3 bar 0-6 bar
Accuracy Dp 1% RDG+3DGT 1% RDG+3DGT 1% RDG+3DGT 1% RDG+3DGT 1% RDG+3DGT 1% RDG+3DGT
Range of measurements Dp 0-65 mbar 0-65 mbar 0-65 mbar 0-65 mbar 0-65 mbar 0-65 mbar
Resolution Dp 0,001 mbar 0,001 mbar 0,001 mbar 0,002 mbar
 
0,005 mbar 0,005 mbar
Direct pressure accuracy 1,5%FS 1,5%FS 1,5%FS 1,5%FS 1,5%FS 1,5%FS
Direct pressure measurement range 0-FS 0-FS 0-FS 0-FS 0-FS 0-FS
Direct pressure relief 0,01 mbar 0,01 mbar 0,1 mbar 0,1 mbar 0,1 mbar 0,1 mbar
Accuracy measuring loss in cc/’ 1%RDG+0,03cc/min 1%RDG+0,03cc/min 1%RDG+0,03cc/min 1%RDG+0,03cc/min 1%RDG+0,03cc/min 1%RDG+0,03cc/min
Measurement range in cc/’ 0-10 cc/min 0-10 cc/min 0-10 cc/min 0-10 cc/min 0-10 cc/min 0-10 cc/min
Measured measurement resolution in cc/’ 0,01 cc/min 0,01 cc/min 0,01 cc/min 0,01 cc/min 0,01 cc/min 0,01 cc/min
Accuracy measure volume in cc - - - - - -
Volume range in cc - - - - - -
Volume measurement resolution in cc - - - - - -
measure unit mbar, bar, psi, mmHg, mmH2O, Pa, HPa, cc/min, cc/h, pressure/s.
Dimensions 180X160X200 mm
Weight 5 kg
Display size 320x240 pixel
Operating temperature range 5-40 °C
RS232 ports 2
RS485 ports 1
“master” usb port 1
“slave” usb port 1
Ethernet port -
I/O signals Start, Stop, Filling, Test, Good, Reject, 3BCD
Auxiliaries I/O signals (optional) -
Number of programs 100
Test archive memory Standard
Password block Yes
Program name Yes, 8 characters
Reference normatives EN 61010-1, EN61326-1 / EN61326/A1, EN61000-3-2 / EN61000-3-2/A14, EN61000-3-3 / EN61000-3-3/A1, EN61000-4-2 / EN61000-4-2/A1, EN61000-4-3 / EN61000-4-3/A1 / EN61000-4-3/A2, EN61000-4-4, EN61000-4-5, EN61000-4-11, EN1779

  • External exhaust solenoid with protection filter
  • External start button
  • External start/abort pushbutton
  • External pushbutton 4 programs selection
  • Start pedal
  • Barcode reader
  • Adhesive label for printer 4500pcs
  • Aux signals extension cable
  • Venturi Vacuum generator
  • Air filter
  • M series manager software
  • TTY
  • Serial protocol
  • External 24 VDC power supply
  • PC serial cable owner - M Series
  • MIXER-07
  • Software Data Manager
  • Thermal printer with peel-off
  • Thermal printer without peel
  • Adapter cable AUX M Series - ET Series
  • Remote Start / Abort / Good / Reject
  • Software "Data Manager"
  • Air filter 5 micron

  • Pneumatics with micro electro valves - (STANDARD)
  • Frontal precision pressure regulator - (STANDARD)
  • Pneumatic module of remote measurements - (STANDARD)
  • Bi-manual logic Start Input
  • High resolution measure - (STANDARD)

Mensagem enviada

Mensagem não enviada

Mensagem não enviada